Skip to Content

Our HS2 Series

HS2 sectional valves built around the required functions

Configure the inlet, working sections, spool functions, controls and outlet as one application-specific valve bank, then send the starting point for technical review.

Placeholder for an HS2 sectional hydraulic valve bank
45 L/minNominal flow
250 barMaximum opening pressure
1–7 sectionsHydraulic Equipment public offer
G3/8 or SAE6Standard port routes

Why sectional

Configure each service within one assembly

Sectional construction is useful when the functions, controls or circuit requirements do not fit a standard fixed-body valve.

Mixed functions

Specify spool behaviour and controls section by section rather than forcing every service into the same arrangement.

Modular construction

Build the bank from inlet, working and outlet sections for a serviceable, application-led assembly.

Control choice

Manual, cable, joystick, pneumatic and assisted-control routes can be reviewed against the intended duty.

Assembly anatomy

Three parts of the valve bank

1

Inlet section

Introduces pressure flow and the selected relief arrangement from the left or right as required.

2

Working sections

One to seven commercially offered services, each reviewed for spool function and control.

3

Outlet section

Completes the return, carry-over/power-beyond or closed-centre requirement within the designed circuit.

Advisory configurator

Build a proposed HS2 enquiry summary

Use one representative section to describe the starting arrangement. Mixed functions can be detailed in photographs, drawings or the enquiry message.

Skip to technical sales

Starting point

Select the known requirements

The result will organise the choices into a readable enquiry summary. It will not generate a confirmed supplier order code.

Configuration overview

Options still checked during specification

Scroll sideways to compare all columns →

AreaTypical choicesWhy it matters
Spool functionDouble acting, single acting, float and mixed arrangementsDetermines work-position and neutral flow paths
PositionerSpring return, detents and assisted shiftingChanges how the operator commands and holds movement
ControlLever, cable, joystick, pneumatic, electro-pneumatic or electro-hydraulicAffects ergonomics, packaging, air/electrical supply and fail behaviour
ReliefInlet and section-level options subject to the final buildMust protect the system within every component rating
OutletOpen centre, carry-over/power beyond or closed centreMust match the pump and downstream circuit

The supplier catalogue describes a wider technical construction range. Hydraulic Equipment's current public commercial offer is one to seven working sections, configured by enquiry.

Quotation inputs

Describe every service the valve must control

Send the machine/application, flow, pressure, section count, required movement for each service, preferred controls, ports, inlet orientation and outlet arrangement. Drawings, photographs and existing valve details are useful.

Enquiry-only assembly

A complete HS2 bank is configured around the requirement and technically checked before supply. The website configurator is a conversation aid rather than a checkout tool.

Send the HS2 requirement

Technical and safety note

Catalogue figures are configuration-dependent. Final selection must be checked against the pump, actuator loads, return pressure, thermal duty and machine circuit. Installation and commissioning must be completed by competent people in accordance with the machine documentation and applicable safety requirements.

Talk to technical sales

Turn the circuit requirements into an HS2 valve-bank enquiry

Send the section-by-section functions and the known hydraulic details. We will help convert them into a technically reviewed assembly.

Ask technical sales